What is the E Cigs Factory Test condition

Item E Cigs Factory Test condition(Test Method) Spec. Mass production Test result Test No.
 E Cigs Factory Function Test Confirm operation function Refer to E Cigs Factory operation instruction of function of specification. Refer specification 5 Pass TR2017036-1
Number of puff E Cigs Factory offer Full charge and full power, with resistance of 1.0ohm. Vape a puff for 3 seconds and stop for 5 seconds until it alarmed for low battery. Record the total amount of vaping puffs. ≥350 2 Pass TR2017036-2
Leaking protection of battery tube Use empty battery tube and assemble battery connection,electrode and sealing ring. Add 10:1 ink on battery electrode and put some clean tissue on the bottom of electrode. Then screw atomizer and place it for 60 minutes. Observe if it leaking by tissue, then unscrew atomizer and add ink again. Circle it for 10 times. No ink on tissue 5 Pass TR2017036-3
 E Cigs Factory Taste Test Oil boiling E Cigs Factory offer Full charge and full power, with resistance of 1.0ohm/1.2ohm/1.5ohm, normal use/record former five puffs before stop vaping for 30 minutes. No oil boiling 5 Pass TR2017036-25
Oil inhale E Cigs Factory Battery indicate red light, with resistance of 1.0ohm/1.2ohm/1.5ohm,normal use/former five puffs before stop vaping for 30 minutes. No oil inhale 5 Pass TR2017036-26
Dry ashing Full charge and full power, with resistance of 1.0ohm/1.2ohm/1.5ohm(use new coil),vaping for 10 seconds and stop for 10 seconds.Circle it for 10 times. No dry ashing 5 Pass TR2017036-27
Surface Technics Reliability Test Wearing resistance test(oil injection surface) E Cigs Factory Fix the sample on testing jig,add 200g weights. Rub it as speed of 35 times/minutes. It can’t show natural mental under stipulate times.(separate paint spraying and printing parts) 1500 times 3 Pass TR2017036-4
Salt Spray test(mental surface) Set NaCl Concentration for 5+-1%,,PH value:6.5-7.2,spray pressure for 0.7-1.8kg/sq. cm,temperature for35℃+-2℃,volume of spray for0.5-3.0ml/80sq. cm,No rusting stipulate times. 24 hours 3 Pass TR2017036-5
 E Cigs Factory Connective  Strength Test Extraction force for drip tip E Cigs Factory Fix the sample on the jig, pull atomizer and drip tip slowly to have Connective  Strength Test. 0.7-1.8Kg 3 Pass TR2017036-6
Bending Strength Test between atomizer and battery(aim at Riveting place) Stack up wood beside two connections and press 5 times with 10 kg strength, last 3 seconds every time. No transformed 2 Pass TR2017036-7
Button Function Test Life E Cigs Factory Fix sample on testing jig, add 500g wights.Have button test as speed of 35 times/minutes, and count those have button functions. 50000times 3 Pass TR2017036-8
Strength Press button in vertical direction with strength meter,record force value when button exactly have function. 250±50g 3 Pass TR2017036-9
Light leak Observe leval of light leaking from different angle when it brights. subjective judgement 3 Pass TR2017036-10
center correction Unilateral excursion from up,down,right and left. <0.2mm 3 Pass TR2017036-11
USB Connector Test Insertion and Extraction Force E Cigs Factory Test with ship USB cable Insertion≤3.57Kgf
Extraction≥1.02Kgf
3 Pass TR2017036-12
center correction Unilateral excursion from up,down,right and left. <0.2mm 3 Pass TR2017036-13
USB Cable Salt Spray Test Set NaCl Concentration for 5+-1%,,PH value:6.5-7.2,spray pressure for 0.7-1.8kg/sq. cm,temperature for 35℃+-2℃,volume of spray for 0.5-3.0ml/80sq. cm,No rusting stipulate times. 8 hours 2 Pass TR2017036-24
USB Cable  Flexing Test hoisting:200g;Angle:+-45 degree;Swing frequency:30RPM;Hang distance:250+-10mm,No broken under stipulate times. 5000 times 2 Pass TR2017036-23
Clearomizer Leakage Test 1.Turn air hole; 2. Open upper cover; 3. Fill e-liquid; 4. Lock upper cover; 5. Open air hole; 6. Place 10  samples  separately as 45 inclined angle; 7. Take them out in sequence, do smoking test as 45 inclined angle; 8. Take 25 puffs as standard for every sample, smoking 3 seconds every puff, then stop for 30 seconds. Finish the same action for 25 times. 9.Put the sample back as 45 inclined angle, and finish others by turns. No leaking 3 Pass TR2017036-13
 E Cigs Factory Clearomizer filling and Leakage Test(For top filling) Use new coil, unscrew upper cover, fill oil around 3/4, screw it, place it for 15 minutes. Then unscrew upper cover , full refill , upper cover still open and place it for 50 seconds. No leaking 5 Pass TR2017036-15
Oil Cup Capacity Test 1. E Cigs Factory Calculate testing oil density: calculate Oil density by fomula ρ=m/v ; weigh net weight for container as Ag, fill 10ml oil into container and weigh as Bg,ρ=m/v=(B-A)/10=Cg/cm3;
2. Weigh atomizer(contain coil),coil:Take new atomizer (contain coil) and weigh as Dg; Take coil from atomizer and then weigh coil alone as Eg;
3. Steep coil and weigh: put coil on atomizer; Fill oil into atomizer, oil filling leval lower than max gas-guide tube of atomizer for 0.5-1mm; steep coil for 15 minutes then take it out; clear extra oil on coil’s appearance(tissue can’t touch with organic and fabrcis)then weigh coil as Fg;
4. Calculate oil contained capacity of coil:calculate by formula v1=m/ρ=(F-E)/C
5. Put coil back into atomizer then fill oil and weigh: drain oil from atomizer,put coil(oil contained) back into atomizer, oil filling till maxmium designed, screw atomizer and weigh it as Gg.
6. Calculate oil contained capacity of coil: calculate capacity of atomizer by formula v2=m/ρ=(G-D)/C
7. capacity of oil cup=capacity of atomizer-capacity of coil(V2-V1)
≤2ml 2 Pass TR2017036-16
Drop Test Drop the sample from 1.5 meters high into solid board within 5mm thick, and drop it twice as horizontal direction. Function normal and no damage in appearance. Normal appearance and  function 3 Pass TR2017036-17
Vibration Test Fix the sample on the test board, set frequency range at 5Hz,and vibrate it as horizontal and vertical direction for 60 minutes. Function normal and no obvious damage in appearance.(Do test with one unit, package included and carton included) Normal appearance and  function 3 Pass TR2017036-18
Low Temperature Storage Test Put the sample into temperature box for -20±2℃ and store for 24 hours, and end the test. Take the sample out and shelve it for four hours with 20±5℃, and observe appearance of the sample, then have electric performance test. Normal appearance and  function 2 Pass TR2017036-19
High Temperature Storage Test Put the sample into temperature box for 40±2℃ and 95%RH , and store for 24 hours, then end the test. Take the sample out and shelve it for four hours in 20±5℃. Observe appearance of the sample and  have electric performance test. Normal appearance and  function 2 Pass TR2017036-20
Hot and Cold Impact Test 1. Put sample into constant temperature humidity chamber and set temperature for -20℃, then store for 120 minutes when temperature come up to preset value;
2. Set temperature for 60℃, then store for 120 minutes when temperature come up to preset value;
3.Do step 1~2, and test for 24 hours in all;
4.End the test, then take sample out and place it in 20±5℃ for 4 hours, then bserve appearance of the sample and  have electric performance test.
Normal appearance and  function 2 Pass TR2017036-21
Twist Test E Cigs Factory Fix the sample and do twist test between battery and atomizer as constant speed. Twist normal under stipulate times. 500 times 2 Pass TR2017036-22
Satety Certification UN 38.3 The United Nation《Recommendations on the transport of dangerous goods》Fifth version amendant 1 and 2, article 38.3
IEC62133 IEC 62133:2012(2nd Edition)
CE EN61000-6-3:2007+A1:2011+AC:2012     EN61000-6-1:2007
RoHS RoHS directive 2011/65 / EU;  IEC 62321:2008;   IEC 62321:2013;  IEC 62321:2015;
TPD Carbonyl emmision According to E Cigs Factory XP-D90-300-3
Metal Dissloving According to E Cigs Factory XP-D90-300-3
Nicotine Consistency According to E Cigs Factory XP-D90-300-3
Material Certification Drip tip needs food grade material Supplier provides reports
Components contact with oil can’t contain  mental element dissloving Refer to TPD mental dissloving test(Test after putting oil for two weeks.)
All material needs RoHs or MSDS reports Supplier provides reports

Leave a Reply